          Position首頁(yè) > Home > Industrial Safety Products > Safety interlock switch > Magnetic induction switch
          LMC3-50 series RFID safety door switch

          1706678051308494.pngimage.png

          With detection confidentiality (unique code can be provided)

          ?Strong anti-interference, safety and reliability.

          ?Safety level PLe can be achieved by using safe dual-channel output technology.

          ?Effectively prevent false positives or false negatives, or artificial abnormal triggers.

          ?Can be used with the safety door.


          395181ccb7a771e30162f6415dc922a.png

          Ordering information

          86b9d0315b563dc534da6381bf695f3.png

          Switch model

          Specification

          Output method

          Encoding method

          LMC3-50-40SNT/5M


          4-core direct wiring with dual output
          5M cable


          NPN

          Universal encoding

          LMC3-50-40SN1/5M

          Unique encoding

          LMC3-50-40SPT/5M

          4-core direct wiring with dual output
          5M cable


          PNP

          Universal encoding

          LMC3-50-40SP1/5M

          Unique encoding

          LMC3-50-60JNT/5M

          6-core direct wiring with dual output and cascading 5M cable

          NPN

          Universal encoding

          LMC3-50-60JN1/5M

          Unique encoding

          LMC3-50-60JPT/5M

          6-core direct wiring with dual output and cascading 5M cable

          PNP

          Universal encoding

          LMC3-50-60JP1/5M

          Unique encoding

          395181ccb7a771e30162f6415dc922a.png

          Model Description


          395181ccb7a771e30162f6415dc922a.png

          Technical parameter

          Safty standard

          Mean Time to Dangerous Failure (MTTFd) (years)

          ISO13849-11EC/EN60947-5-1IEC/EN60947-5-3

          ≥30 years

          Safety classification

          Class 4 switch according to IS0 13849-1/suitable for PLe/PL

          Certification

          CE

          Horizontal working distance

          Conduction, min:10mm

          Vertical working distance

          Conduction, min:8mm

          Operating voltage

          24V DC±15%

          Operating current

          150mA

          Response time

          60ms

          The protection grades

          IP65, IP67 (customized)

          Operating frequency

          lHZ

          Working temperature

          -10~+55℃

          Relative humidity

          5%~95%

          Material

          Flame-retardant thermoplastic


          395181ccb7a771e30162f6415dc922a.png

          Shape and installation dimensions

          尺寸圖.pngLMC3-50.png


          395181ccb7a771e30162f6415dc922a.png

          Approach pattern of LMC3-50 switch

          1706679390304986.png1706679459242220.png


          395181ccb7a771e30162f6415dc922a.pngLMC3-50 switch induction distance


          Misalignment deviation

          breakover

          disconnect

          Alignment signal

          Horizontal alignment

          The deviation is within 4 mm in the X direction.Y direction induction 0~10mmY direction induction distance > 25mmLMC3-50.png
          The deviation is > 5mm and < -5mm in the x direction.Not recommended

          Vertical alignment

          The deviation is within 4mm of soil in X direction.Z direction induction distance 0~8mmZ direction induction distance > 23mmLMC3-510.png
          The deviation is > 5mm and < -5mm in the x direction.Not recommended


          395181ccb7a771e30162f6415dc922a.png

          Hookup

          Two-way output with cascade connection diagram

          serial number

          Signal definition

          colour

          explain

          1706680404188780.png

          1

          24V

          palm

          Power supply positive

          2

          0V

          blue

          Negative power supply

          3

          output1

          black

          Safety output 1

          4

          output2

          white

          Safety output 2

          5

          input1

          green

          Cascade input 1

          6

          input2

          yellow

          Cascade input 2


          395181ccb7a771e30162f6415dc922a.pngLegend of connection between RFID switch and safety relay module (dual output)


          接線圖.png



          395181ccb7a771e30162f6415dc922a.png

          RFID switch approach pattern

          Led display

          Signal state

          State description

          input

          output

          The red light is always on.

          Yes/No.

          break

          No actuator or incomplete alignment (universal coding)

          The red light is on for 1 second and then flashes twice (alternately).

          Yes/No.

          break

          No actuator or incomplete alignment (unique code)

          Red light flashing at 4Hz

          effective

          break

          Output overload

          Green light flashes at 1Hz.

          be invalid

          break

          No input signal (dual output is not applicable)

          The green light is always on

          effective

          through

          Induction is normal

          Alternate flashing of traffic lights

          effective

          break

          Label is not registered.


          Related Products
          Download
          PDF file download
          Video file download
          Previous

          Contact us

          400-881-6062

          Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

          E-Mail: info@lh-safety.com

          Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

          (Greenland East Coast International Plaza-Room A 313)

          Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

          Online service

          Online message

        2. Click to refresh
        3. 主站蜘蛛池模板: 亚洲综合无码日韩国产加勒比| 亚洲超碰97无码中文字幕| 中文字幕乱码无码人妻系列蜜桃| 粗大挺进尤物人妻一区二区| 国产香蕉一区二区在线网站| 中文无码一区二区视频在线播放量| 国产成人av性色在线影院| 亚洲AV无码精品一区二区三区| 国产精品手机免费| 少妇三级全黄| 色二区| 亚洲青涩中文字幕| 一区二区在线中文字幕| 2020年最新国产精品正在播放| 精品一区二区三区av天堂| 久久精品国产中文字幕| 中文字幕在线观看www| 亚洲国产日韩精品久久| 久久99久久99精品免视看国产| 97视频精品全国免费观看| 色欲天天天综合网| 亚洲香蕉伊综合在人在线| zzjjzzjjzzjj| 盐山县| 一本久道久久综合五月丁香| 国产精品最新视频| 欧美88888| 免费国产黄网站在线观看视频| 国产无遮挡裸体免费视频 | 曰批免费视频播放免费直播| 亚洲qingse中文| 国产一区内射最近更新| 国产三级av在线播放| 五月天成人社区| 国产精品色一区二区三区| 人妻有码中文字幕在线不卡| 日韩第一页在线| 337p日本欧洲亚洲大胆人人| 亚洲成a人在线播放www| 国产午夜精品一区二区三| 国产综合久久亚洲综合|