          LMC3-52 magnetic induction safety switch
          圖片1.png

          ·Miniaturized design,(compatible with 30mm aluminum frames) for easy installation.

          ·Adopts redundant internal circuits(dual CPU mutual inspection)and self-diagnostic function.

          ·Intelligent diagnosis and status display:Integrated LED indicators,provide real-time feedback on door switch status and fault information, facilitating quick troubleshooting.

          ·Support series connection of multiple switches(up to 30 switches can be connected),adapting to complex equipment layouts.

          ·The actuator coding function has low-level and high-level settings. It performs self-learning to match the sensor during initial installation. The high level function is unique and non-interchangeable.

          ·Equipped with magnetic latching function,with a magnetic holding force of up-to 15N,which can replace door magnets.


          395181ccb7a771e30162f6415dc922a.png

          Selection catagory

          Configuration type

          Coding type

          Output mode

          Lead wire mode

          Direct outlet

          Cable length

          Model

          Basic function

          Universal coding

          NPN

          Direct outlet

          3M

          LMC3-52-J2-N-Z3

          5M

          LMC3-52-J2-N-Z5

          10M

          LMC3-52-J2-N-Z10

          M12 Connector

          /

          LMC3-52-J2-N-M12

          PNP

          Direct outlet

          3M

          LMC3-52-J2-P-Z3

          5M

          LMC3-52-J2-P-Z5

          10M

          LMC3-52-J2-P-Z10

          M12 Connector

          /

          LMC3-52-J2-P-M12

          Unique coding

          NPN

          Direct outlet

          3M

          LMC3-52-J1-N-Z3

          5M

          LMC3-52-J1-N-Z5

          10M

          LMC3-52-J1-N-Z10

          M12 Connector

          /

          LMC3-52-J1-N-M12

          PNP

          Direct outlet

          3M

          LMC3-52-J1-P-Z3

          5M

          LMC3-52-J1-P-Z5

          10M

          LMC3-52-J1-P-Z10

          M12 Connector

          /

          LMC3-52-J1-P-M12

          Standard

          Universal coding

          NPN

          Direct outlet

          3M

          LMC3-52-B2-N-Z3

          5M

          LMC3-52-B2-N-Z5

          10M

          LMC3-52-B2-N-Z10

          M12 Connector

          /

          LMC3-52-B2-N-M12

          PNP

          Direct outlet

          3M

          LMC3-52-B2-P-Z3

          5M

          LMC3-52-B2-P-Z5

          10M

          LMC3-52-B2-P-Z10

          M12 Connector

          /

          LMC3-52-B2-P-M12

          Unique coding

          NPN

          Direct outlet

          3M

          LMC3-52-B1-N-Z3

          5M

          LMC3-52-B1-N-Z5

          10M

          LMC3-52-B1-N-Z10

          M12 Connector

          /

          LMC3-52-B1-N-M12

          PNP

          Direct outlet

          3M

          LMC3-52-B1-P-Z3

          5M

          LMC3-52-B1-P-Z5

          10M

          LMC3-52-B1-P-Z10

          M12 Connector

          /

          LMC3-52-B1-P-M12

          High-function typle


          Universal coding

          NPN

          Direct outlet

          3M

          LMC3-52-G2-N-Z3

          5M

          LMC3-52-G2-N-Z5

          10M

          LMC3-52-G2-N-Z10

          M12 Connector

          /

          LMC3-52-G2-N-M12

          PNP

          Direct outlet

          3M

          LMC3-52-G2-P-Z3

          5M

          LMC3-52-G2-P-Z5

          10M

          LMC3-52-G2-P-Z10

          M12 Connector

          /

          LMC3-52-G2-P-M12

          Unique coding

          NPN

          Direct outlet

          3M

          LMC3-52-G1-N-Z3

          5M

          LMC3-52-G1-N-Z5

          10M

          LMC3-52-G1-N-Z10

          M12 Connector

          /

          LMC3-52-G1-N-M12

          PNP

          Direct outlet

          3M

          LMC3-52-G1-P-Z3

          5M

          LMC3-52-G1-P-Z5

          10M

          LMC3-52-G1-P-Z10

          M12 Connector

          /

          LMC3-52-G1-P-M12


          395181ccb7a771e30162f6415dc922a.pngModel description

          1750041376195449.png



          395181ccb7a771e30162f6415dc922a.pngM12 Connection cable selection

          M12 connection cable

          image.png

          Basic function cable(5-pin, 5-core)

          LMC3-52--XL-P55C3

          LMC3-52-XL-P55C5

          LMC3-52-XL-P55C10

          Standard-type cable(8-pin,8-core)

          LMC3-52-XL-P88C3

          LMC3-52-XL-P88C5

          LMC3-52-XL-P88C10

          High-function type cable(12-pin,10-core)

          LMC3-52-XL-P1210C3

          LMC3-52-XL-P1210C5

          LMC3-52-XL-P1210C10


          395181ccb7a771e30162f6415dc922a.pngIndicator light description

          image.png


          Indicator light name

          Light color

          Status

          Status description

          Status of OSSD

          Detection status of the actuator

          Large indicator light

          Green

          Light up

          In normal operation

          ON

          Detection status

          Green

          Flashing

          (high- speed)

          Switching coding level from low to high, or teaching the matcher

          OFF

          Detected matcher is incorrect

          Green

          Flashing

          Switching coding level from low to high, or teaching the matcher

          OFF

          Detected matcher is incorrect。

          Red and green alternating

          Flashing

          (high- speed)


          An untaught actuator is detected when operating at "high" coding level

          OFF

          Detected matcher is incorrect。

          Error during coding level switching

          Not fixed

          Red

          Light up

          Door is in open state.

          OFF

          Non-detection status

          Flashing

          (high- speed)


          Error state.The sensor detects an abnormality

          OFF

          Not fixed

          Turn off

          Power OFF

          OFF

          Not fixed

          OSSD indictor light

          Green

          Light up

          OSSD is on

          ON

          Detection status

          Flashing

          OSSD is on,but the door is in an unstable state such as half-open

          ON

          Detection status

          Red

          Light up

          OSSD is off

          OFF

          Not fixed

          Input indicator light

          Green

          Light up

          Safety input is on

          Not fixed

          Detection status

          Flashing

          Self- holding release waiting state(waiting for reset input)

          OFF

          Not fixed

          Turn off


          Safety input is OFF,or other states.

          OFF

          Detection status


          395181ccb7a771e30162f6415dc922a.pngTechnical parameter

          Model

          LMC3-52-J

          LMC3-52-B

          LMC3-52-G

          Type

          Basic function type

          Standard type

          High-function type

          Detection distance


          Front side

          sao(OFF→ON)

          10mm

          sar(ON→OFF

          18mm

          Side face

          sao(OFF→ON)

          6mm

          sar(ON→OFF

          14mm

          Response time(ms)*1

          Detection action

          Detection→Non-detection

          20ms+2ms×(total number of cascade-connected units -1)

          Non-detection→ Detection

          30ms+25ms×(total number of cascade-connected units-1)

          Door operation

          Allowable operating frequency

          3Hz

          Magnetic attraction

          Magnetic holding force

          15N

          Cascade connection

          Standard

          -

          Maximum 30 units

          Control output(OSSD output)

          Output type

          Transistor output×2

          Maximum load current

          PNP:<=150mA、NPN:<=100mA

          Residual voltage during ON state

          Maximum 2.5V(with 5m cable)

          Voltage in OFF state

          Maximum 2.0V(with 5m cable)

          Leakage current

          Maximum 0.5mA

          Maximum load capacity

          2.2μF

          Load wiring resistance

          Maximum 2.5Ω

          Detection distance

          Front side

          sao(OFF→ON)

          10mm

          sar(ON→OFF

          18mm

          Side face

          sao(OFF→ON)

          6mm

          sar(ON→OFF

          14mm

          Response time(ms)*1

          Detection action

          Detection→Non-detection

          20ms+2ms×(total number of cascade-connected units-1 )

          Non-detection→ Detection

          30ms+25ms×(total number of cascade-connected units-1 )

          Door operation

          Allowable operating frequency

          3Hz

          Magnetic attraction

          Magnetic holding force

          15N

          Cascade connection

          Standard

          -

          Maximum 30 units

          Control output(OSSD output)

          Output type

          Transistor output×2

          Maximum load current

          PNP:<=150mA、NPN:<=100mA

          Residual voltage during ON state

          Maximum 2.5V(with 5m cable)

          Voltage in OFF state

          Maximum 2.0V(with 5m cable)

          Leakage current

          Maximum 0.5mA

          Maximum load capacity

          2.2μF

          Load wiring resistance

          Maximum 2.5Ω

          AUX output(Non-safety system output)

          Output type

          Transistor output

          Number of outputs

          1

          Maximum load current

          50mA

          Residual voltage during ON state

          Maximum 2.5V(with 5m cable)

          External input (Short-circuit current)

          Safety input

          -

          Approximately 1.5mA×2

          Reset/EDM Input

          -

          Approximately 5mA×1

          Power supply

          Power supply voltage

          24VDC±20% including ripple(P-P)10%Class2

          Power comsuption

          0.8W*2

          Protection circuits

          Power reverse connection protection、each output short-circuit protection、eacn output surge protection、output reverse connection protection

          Safety related parameters

          ISO13849-1 IEC/EN60947-5-1 IEC/EN60947-5-3

          Compliant with ISO 13849-1 catagory 4 switch /suitable for PLe/PLd

          MTTFd≥30 years

          CE

          Environmental resistance

          Enclosure protection class

          IP65,IP67IP68 requires customization,pls consult the sales department before placing an order

          Operating ambient temperature

          -20℃ to +55℃(No freezing)

          Storage ambient temperature

          -25℃ to +70℃(No freezing)*3

          Operating ambient humidity

          5% to 95%RH

          Storage ambient humidity

          5% to 95%RH

          Vibration resistance

          10 to 55HZ、double amplitude 3.0mm、5 minutes for each directions X、Y、Z

          (IEC60947-5-3)

          Shock resistance

          30G,6 times for each direction X、Y、Z(IEC60947-5-3)

          Material

          Sensor

          Host server

          Housing

          Flame-retardant grade thermoplastic

          Cable

          PVC

          Matcher

          Housing

          Flame-retardant grade thermoplastic

          *1 The risk time specified in IEC60947-5-3 is 150 ms+2 ms×(total number of cascade-connected units-1) 

          *2 Excluding load current。

          *3 For long-term storage ,pls store in an environment below 55℃

          395181ccb7a771e30162f6415dc922a.pngProduct dimension drawing

          1750041793170171.png1750041831401457.png


          395181ccb7a771e30162f6415dc922a.pngWiring diagram

          1750042721223258.png

          Pin number

          Signal definition

          Color

          Description

          1

          24V

          Brown

          Positive power supply

          2

          OSSD2

          White

          safety output 2

          3

          0V

          Blue

          Negative power supply

          4

          OSSD1

          Black

          safety output 1

          5

          AUX output

          Gray

          Auxiliary output 1


          1750042818626171.png

          Pin number

          Signal definition

          Color

          Description

          1

          AUX output 1

          Gray

          Auxiliary output 1

          2

          24V

          Brown

          Positive power supply

          3

          Not used

          Red

          Not used

          4

          safety input 2

          Yellow

          Cascade input 2

          5

          OSSD1

          Black

          safety output 1

          6

          OSSD2

          White

          safety output 2

          7

          0V

          Blue

          Negative power supply

          8

          safety input 1

          Green

          Cascade input 1


          1750043082195521.png

          Pin number

          Signal definition

          Color

          Description

          1

          24V

          Brown

          Positive power supply

          2

          Safety input 1

          Green

          cascade input 1

          3

          0V

          Blue

          Negative power supply

          4

          OSSD1

          Black

          Safety output 1

          5

          AUX output1

          Gray

          Auxiliary output 1

          6

          Safety input 2

          Yellow

          cascade input 2

          7

          OSSD2

          White

          Safety output 2

          8

          Self-holding/EDM selection input

          Pink

          Self-holding/EDM selection input

          9

          Not used

          Red

          Not used

          10

          11

          Reset/EDM input

          Purple

          Reset/EDM input

          12

          1750045067392088.png1750045195573398.png1750045324661430.png
          Wiring example for cascade connection

          High-functioning self-protection function:

          圖片3.png

          The self-protection function is a feature that prevents the OSSD from automatically switching from OFF state to ON state. This function can prevent accidental startup or restart of the device. To restore from the state where the self-protection is active to the normal operating state, a reset operation is required.

          The basic function type and standard type can not set the self-protection function. The self-protection function is fixed to "Automatic"

          The self-protection function of high-function type can be selected from two types:"Automatic"and"Manual".

          "Automatic"and"Manual" here refer to following actions:

          Automatic:

          When the OSSD meets the condition for switching to the ON state(for example, the door is in the closed state), it shall switch to the ON state immediately.

          Manual:

          Even if the OSSD meets the condition for switching to the ON state, it shall remain in the OFF state(self-holding state).

          <Release of self-holding state>

          To switch the OSSD to the ON state and start the equipment, a reset operation must be performed under the conditions that the door with GS(non-contact)installed is closed and the equipment is ready for startup.Through this,the OSSD will switch to the ON state,and the self-holding state can be released.

          Setting of Self-holding function

          Self-holding function

          EDM function

          Reset/EDM input(Purple)

          Self-holding/EDM function selection input(Pink)

          Automatic

          Not in use

          0V

          0V

          Automatic

          in use

          Connect to 24 V via NC contact of relay

          Open

          Manual

          Not in use

          Connect to 24 V via NO reset switch

          Connect to 24 V

          Manual

          in use

          Connect to 24V via NO reset switch and NC contact of relay

          Connect to 24 V



          Related Products
          Download
          PDF file download
          Video file download
          Previous

          Contact us

          400-881-6062

          Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

          E-Mail: info@lh-safety.com

          Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

          (Greenland East Coast International Plaza-Room A 313)

          Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

          Online service

          Online message

        2. Click to refresh
        3. 主站蜘蛛池模板: 国产成人免费a在线视频| 口爆少妇在线视频免费观看 | aaaaa国产毛片| 狠狠亚洲色一日本高清色| 久久久久久亚洲AV无码专区| 亚洲精品色午夜无码专区日韩| 深夜福利视频网站| 亚洲精品乱码久久久久久蜜桃不卡 | 国产精品va在线观看无码不卡| av在线亚洲一区| 男人用嘴添女人下身免费视频| 国产又色又爽无遮挡免费动态图| 国产成人一区二区三区| 国产麻传媒精品国产av| 亚洲精品乱码久久久久久日本蜜臀 | 日韩在线视频线观看一区| 中文字幕av久久| 国产 亚洲 制服 无码 中文| 欧美和黑人XXXX猛交视频| 日本一高清二区视频久二区| 亚洲精品字幕| 一本色道久久综合熟妇人妻| 国产精品午夜av福利| 国产精品www夜色影视| 国产日韩欧美一区二区三区乱码| 欧美性色黄大片| 日韩av二区三区一区| 国产毛片欧美毛片久久久| 欧美人与牲禽动交精品| 久久久久久无码午夜精品直播| 亚洲国产精品美女久久久久| 国产精品久久久久网站| 国产精品视频区| 午夜无码免费福利视频网址| 国产超爽精品国语对白| 精品国产一区二区三区四区精华液 | 亚洲日韩精品a∨片无码| 亚洲天堂成人一区二区三区| 日本狠狠干| 夜夜偷天天爽夜夜爱| 欧美成妇人吹潮在线播放|